High-Dose TXA Is Associated with Less Blood Loss Than Low-Dose TXA without Increased Complications in Patients with Complex Adult Spinal Deformity.
Publication Title
The Journal of bone and joint surgery. American volume
Document Type
Article
Publication Date
12-4-2024
Keywords
Humans; Female; Male; Blood Loss, Surgical; Middle Aged; Retrospective Studies; Tranexamic Acid; Antifibrinolytic Agents; Dose-Response Relationship, Drug; Aged; Spinal Fusion; Adult; Spinal Curvatures; Postoperative Complications; washington; swedish; swedish neurosci
Abstract
BACKGROUND: Tranexamic acid (TXA) is commonly utilized to reduce blood loss in adult spinal deformity (ASD) surgery. Despite its widespread use, there is a lack of consensus regarding the optimal dosing regimen. The aim of this study was to assess differences in blood loss and complications between high, medium, and low-dose TXA regimens among patients undergoing surgery for complex ASD.
METHODS: A multicenter database was retrospectively analyzed to identify 265 patients with complex ASD. Patients were separated into 3 groups by TXA regimen: (1) low dose (<20-mg/kg loading dose with ≤2-mg/kg/hr maintenance dose), (2) medium dose (20 to 50-mg/kg loading dose with 2 to 5-mg/kg/hr maintenance dose), and (3) high dose (>50-mg/kg loading dose with ≥5-mg/kg/hr maintenance dose). The measured outcomes included blood loss, complications, and red blood cell (RBC) units transfused intraoperatively and perioperatively. The multivariable analysis controlled for TXA dosing regimen, levels fused, operating room time, preoperative hemoglobin, 3-column osteotomy, and posterior interbody fusion.
RESULTS: The cohort was predominantly White (91.3%) and female (69.1%) and had a mean age of 61.6 years. Of the 265 patients, 54 (20.4%) received low-dose, 131 (49.4%) received medium-dose, and 80 (30.2%) received high-dose TXA. The median blood loss was 1,200 mL (interquartile range [IQR], 750 to 2,000). The median RBC units transfused intraoperatively was 1.0 (IQR, 0.0 to 2.0), and the median RBC units transfused perioperatively was 2.0 (IQR, 1.0 to 4.0). Compared with the high-dose group, the low-dose group had increased blood loss (by 513.0 mL; p = 0.022) as well as increased RBC units transfused intraoperatively (by 0.6 units; p < 0.001) and perioperatively (by 0.3 units; p = 0.024). The medium-dose group had increased blood loss (by 491.8 mL; p = 0.006) as well as increased RBC units transfused intraoperatively (by 0.7 units; p < 0.001) and perioperatively (by 0.5 units; p < 0.001) compared with the high-dose group.
CONCLUSIONS: Patients with ASD who received high-dose intraoperative TXA had fewer RBC transfusions intraoperatively, fewer RBC transfusions perioperatively, and less blood loss than those who received low or medium-dose TXA, with no differences in the rates of seizure or thromboembolic complications.
LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Area of Special Interest
Neurosciences (Brain & Spine)
Area of Special Interest
Orthopedics & Sports Medicine
Specialty/Research Institute
Neurosciences
Specialty/Research Institute
Orthopedics
Specialty/Research Institute
Surgery
DOI
10.2106/JBJS.23.01323